iahawkeye83 stop worrying that disconnected drops cause ingress and egress. They really don’t, since the center conductor is even with the end of the connector impedance effectively becomes infinite, the signal does not radiate, and it does not act like an antenna. I did plant maintenance for years tracking and fixing ingress and egress.
On the other hand, damaged cables and loose connectors do because the shield and center conductor are different lengths so the impedance isn’t 0, 75, or infinite.
Also, as ingress/egress has become a more impactful issue, the monitoring/tracking systems have become much better and often linked to ticketing systems. Techs are dispatched as needed to hunt down and fix noise sources causing problems. Leakage tracking is frequently handled by an automated system installed in all tech trucks with GPS locating. Again it’s connected to ticketing systems for tech dispatch as needed.
Are you suffering any packet loss with your connection?